A Wandering Atrial Pacemaker in Inferior Wall Infarction. Escape or Survival Rhythm? A Case Reports

1. Abstract

Coronary sinus rhythm is an ectopic atrial rhythm supposedly originating from a pacemaker at the mouth of the coronary sinus; recognized in the electrocardiogram by P-waves that are inverted in leads II, III, and VF with a normal or prolonged P-R interval. In myocardial infarction, this presentation can reveal a wandering atrial pacemaker. We present a case of a wandering atrial pacemaker with inferior wall MI complicated by complete atrioventricular block.

2. Introduction

Coronary sinus rhythm is an ectopic atrial rhythm supposedly originating from a pacemaker at the mouth of the coronary sinus; recognized in the electrocardiogram by P-waves that are inverted in leads II, III, and VF with a normal or prolonged P-R interval. In myocardial infarction this presentation can reveal a wandering atrial pacemaker. We present a case of wandering atrial pacemaker with inferior wall MI complicated by complete atrio-ventricular block.

3. Case report

A 86-year-old woman was admitted to emergency department of a comminatory hospital due to persisting angina for an hour and syncope. Pain was 4/10 on scale His She had no previous medical history, a non-smoker. Electrocardiogram (ECG) showed ST segment elevation in leads II, III and VF and reciprocal ST segment depression in leads V1–V6. She was treated before the arrival of our prehospital team with dual oral antiplatelets such us aspirin 250 mg and clopidogrel 300 mg, intra venous loading doses of unfractionated heparin 50 mg and atropine (0,5 mg) for brady arrhythmia. On physical examination by our prehospital physician the cardiac sounds and breathing were normal on auscultation. The patient was dizzy and somnolent. Her pulse was irregular at 50 bpm, her blood pressure was 50/30 mm Hg. The ECG showed ST elevation in leads II, III, Vf, V3, V4, V3R and V4R. an inverted P wave was noted in inferior leads consistent with coronary sinus rhythm complicated by a complete atrio-ventricular dissociation (Figure 1). She was medicated by Dobutamine at 10 γ/Kg/ min with Norepinephrine at 0,5 mg/h. the patient was transferred to Cath lab for primary Percutaneous Coronary Intervention (PCI). On the way, the ECG has changed and demonstrate Second Degree Heart Block (Mobitz type 2), ST segment elevation in leads II, III, Vf, V1, V3, V4 and V6 with low atrial rhythm (Figure 2). On admission she was conscious, heart rhythm was irregular at 65 bpm, and blood pressure 80/50 mmhg. Serum troponin 0.30 ng/mL (normal range (NR) 0–0.14 ng/mL). His electrocardiogram showed sinus tachycardia with decrease in ST segment elevation (Figure 3). After an initial evaluation, coronary angiography (CAG) was immediately performed and revealed total occlusion with a thrombus in the proximal segment of the right coronary artery (RCA) with a TIMI 0 flow. A Laying bare stent of (3 * 15mm) was placed with good result. During the course several ventricular Fibrillation occurred treated by electrical shock. After coronary angioplasty the ECG showed new-onset atrial fibrillation (AF) (Figure 4). The transthoracic echocardiography performed too days later revealed hypokinesia of the inferior wall with a good left ventricular ejection.

4. Discussion

A wandering pacemaker is a sign of cardiac irritability in the atrial. This dysrhythmia may occur in normal hearts as a result of fluctuations in vagal tone. Schamroth and Goldberg [2] attempted to clarify the definition of wandering pacemaker in 1972. they explained the mechanism of the wandering pacemaker as an escape rhythm overloaded with extreme bradycardia. They postulated that the sinus bradycardia was considered to be the main cause of the escape beat which occur in the first place, and it is a benign physiological condition. New theory concerning the wandering.

5. Conclusion

This case is presented to highlight the possibility of WAP and hypotension and a cardiac output status with inferior myocardial infarction. PAW occurs on the occasion of a change of balance between sympathetic and parasympathetic tone this during this consequent rhythm as Benin can indicate a different speech. This may be a most enriching contribution when future studies are needed to determine if WAP in MI was B flat or a benign heart rate note

Reference

1. Shakir DK, Arafa SOE. Right atrial infarction, atrial arrhythmia and inferior myocardial infarction form a missed triad: A case report and review of the literature. Can J Cardiol. 2007; 23(12): 995-997.

2. Schamroth L, Goldberg M. The concept of a wandering pacemaker. Heart Lung. 1972; 1 (4): 519-522.

3. Monfredi O, Dobrzynski H, Mondal T, Boyett MR, Morris GM. The anatomy and physiology of the sinoatrial node a contemporary review. Pacing Clin Electrophysiol. 2010; 33(11): 1392-1406.

4. Hannibal RN. Wandering Atrial Pacemaker and Multifocal Ectopic Atrial Tachycardia Advanced Critical Care. 2015; 26 (1): 73-76

5. Aburawi EH, Narchi H, Souid AK. Persistent wandering atrial pacemaker after epinephrine overdosing – a case report. BMC Pediatr. 2013; 13: 1.

Mounir Naija. A Wandering Atrial Pacemaker in Inferior Wall Infarction. Escape or Survival Rhythm? A Case Reports. Annals of Clinical and Medical Case Reports 2021